ICOM 746 Temperature Measurements

The ICOM 746-Pro has acquired a history of NEC 1678G (IC-151) MMIC and driver transistor 2SK2975 failures. The failure of IC-151 appears to be a combination of ESD damage from electrostatic charge on the antenna entering IC-151, and perhaps thermal heat.