COAX Stub Harmonics Filters for Multi Contest Station
Description
This resource details the construction and performance of coaxial stub filters designed to attenuate harmonics in multi-station contest environments. The filters are particularly useful for preventing receiver overload in adjacent stations when operating on lower bands. The article explains that two filters, one for CW and one for SSB, should be used in series to cover an entire band effectively. Each filter provides approximately 25 dB attenuation on the second harmonic (2f), with two filters in series achieving about 40 dB. By optimizing the coax length (multiples of lambda/4) between the PA and filters, total attenuation can reach up to 75 dB. The page includes measurement results obtained with a Keysight Fieldfox VNA, showing SWR and attenuation for 80m, 40m, and 20m bands. Specific attenuation figures are provided for 2nd, 3rd, 4th, and 5th harmonics for each band, demonstrating effectiveness in reducing interference.